. The Containerised system is built into a 3 compartment ISO Container.There is a 100 KVA diesel generator in one end in a fully acoustic compartment which also has storage space for the centrifugal pump. The centre compartment houses the umbilical for the cannon, the hydraulic power pack. and a storage frame for the cannon. The control room is at the other end and houses the CCTV monitoring and computerised control system.

SPECIFICATION:

Generator:100 KVA 415 V 50 HZ  Diesel Driven

Manway Cannon:All stainless steel with Chemical protection

Centrifugal Pump:950 litres/minute (251 USG minute) @ 18 Bar (261 psi) Diesel or water  80 Deg C Maximum Hydraulic Power:0.75 kW fixed displacement flow controlled.

Control:Manual joystick or automatic software control.

Gas Detection:Oxygen and LEL detection with alarm and auto shutdown.

Container:Accoustic engine compartment, Insulated air conditioned control room Umbilical:Standard 100 Mtr optional 150 Mtr extension.

Cannon operation:Horizontal tank shell or roof operation.

CCTV:Real time recording and playback via DVD recorder.

Software:Interactive software control and monitoring with graphical representation  

ITEM

AREA

CERTIFICATION

WEIGHT

PART No

Control Container

Safe area.

CE

12,000 KG

CONT203/SA

Manway Cannon

ZONE 1

 II  2G ck T3

120 KG

700V3 NS/FP/E/GD

Centrifugal Pump

ZONE 1

II  2G ck T3

1400 KG

NES-CP-ST-45

Power Reel

ZONE 1

II  2G ck T3

425 KG

PWR/SRU/45

 

Umbilical

ZONE 1

II  2G ck T3

N/A

MCUMB/100

copyright 1996-2010 by Non Entry Systems Ltd (NESL)